European Reaction to Fire Classification System (Euroclasses).

EQUITONE’s A2-s1,d0 fire performance classification means our materials are classed as non-combustible in Scotland and of limited combustibility in England and Wales, emit little or no smoke and produce no flaming droplets or particles within the first 10 minutes of fire exposure. This means our materials do not contribute to the.

The European classifications based on the EN13501-1 standard break down into codes. Products that have been given a fire rating on the European Classification will look like the following: A2, s1,d1. This classification shows the properties of a product based on 3 criteria. There are 7 reaction to fire classifications levels available.

Cladding Fire Rating Guide - VIVALDA.

B-s2,d0: A2-s1,d0: Rockpanel Natural: B-s2,d0: Rockpanel Ply: B-s2,d0: Rockpanel Lines: B-s2,d0: Aluminium or Steel sub-construction When fixed with blind rivets and application of premium FS-Xtra boards, in combination with mineral wool insulation, this meets the requirements for A2-s1,d0.B s1 d0 acc. to EN 13501. B s2 d0 acc. to EN 13501. C s1 d0 acc. to EN 13501. C s2 d0 acc. to EN 13501. FR classification is valid for a very specific end use conditions applicable to product and individual brand. Please contact our FR Product Champion for end use conditions, CE1, DoP and FR classification report.Classification according to European Standard EN 13501-1 Definition Construction products Floorings non-combustile materials A1 A1 fl A2 - s1 d0 A2 - s2 d0 A2 - s3 d0 A2 - s1 d1 A2 - s2 d1 A2 - s3 d1 A2 - s1 d2 A2 - s2 d2 A2 - s3 d2 A2 fl - s1 A2 fl - s2 combustible materials - very limited contribution to fire B - s1 d0 B - s2 d0 B - s3 d0 B.


The new regulations ban the use of combustible materials in external wall systems and balconies. From now on, developments must use materials that are A2-s1, d0 rated or Class A1 under the European classification system (Euroclass) set out in the standard BS EN 13501-1 subject to exemptions.Interrelationship between European and existing Danish fire classification. Existing Danish classification European class Materials. Non combustible A2 - s1, d0 Class A B - s1, d0 Class B D - s2, d2. Coverings. Class 1 K B - s1, d0 Class 2 K D - s2, d0. Load bearing, non separating building components. BS - 30 R 30 A2 - s1. d0 BS - 60 R 60 A2.

Final table in Commission Decision (Official Journal January 2003) Classes of Reaction to Fire Performance for Wood-based panels Solid wood panels 400 12 D-s2,d0 DFL-s1 Plywood 400 9 D-s2,d0 DFL-s1 OSB board 600 9 D-s2,d2 DFL-s1 Cement-bonded particleboard 1000 10 B-s1,d0 BFL-s1 Fibreboards, MDF 600 9 D-s2,d0 DFL-s1 Fibreboards, Soft 250 9 E EFL 400 9 E EFL 600 9 D-s2,d0 DFL-s1.

Read More

BS EN 13501 is the European standard which provides the reaction to fire classification procedure for all construction products, including products incorporated within building elements.. - very limited contribution to fire. B -s1 d0: B - s1 d1: B - s1 d2: Bfl - s1: Bfl -s2: B - s2 d0: B - s2 d1: B - S2 d2: B - s3 d0: B - s3 d1: B - s3 d2: C.

Read More

Understanding Fire Ratings. The fire rating system in regard to wallpapers can be difficult to understand and obviously for absolute accuracy and certainty you should always consult an expert in the field such as a Specifier, Trade Body or Testing Body.

Read More

In the table below you will find Euroclasses according to classification standard EN 13501-1 Fire classification of construction products and building elements - Part 1 The classifications use test data from reaction to fire tests. EuroclassesA1 A2-s1,d0.

Read More

The system, when used over a mineral wool insulation, has A2-s1,d0 fire classification in accordance with BS EN 13501-1:2007 and can therefore be used with no height or boundary restrictions. Lightweight brick slips. As well a traditional slip range we have developed a lightweight slip system with the aesthetics of traditional brickwork.

Read More

A classification according to EN 13501-01 consists of a main classification (A1 to F) with a sub-classification for smoke production (s1 to s3) and a sub classification for burning drops or parts (d0 to d2) and determines the reaction to fire of the product itself.

Read More

ME010 complies with the reaction to fire classification Class B-s3, d0 according to EN13501-1 when used as a monolithic breather membrane, linear gap or window perimeter membrane seal, in conjunction with SP025 Fire Membrane Adhesive. Class B-s1, d0 achieved.

Read More

Please note though, that the opposite is not the case. A Class 0 product will not automatically be classed as B under EN13501-1. EN13501-1 adds two additional test criteria; smoke generation and burning droplets. So a product rated B-s1-d0 will have the equivalent to a Class 0 rating, with little or no smoke (s1) and no burning droplets (d0).

Read More

The European classification (euroclasses) is defined in European standard EN 13501-1.. d0 d1: B: s1 s2 s3: d0 d1: C: s1 s2 s3: d0 d1: M2: D: s1 s2 s3: d0 d1: M3: M4 rating (noon-drip) All classes other than E-d2 and F: M4:. Sotexpro is a French manufacturer of flame retardant decorative fabrics (FR rating) with more than 40 years of.

Read More

There is a smoke classification of either s1, s2 or s3. s1 represents the highest level of performance, s3 represents the lowest level of performance. d0 There is a classification for flaming droplets and particles during the tests of d0 to d2. d0 represents the highest level of performance, d2 represents the lowest level of performance.

Read More